RJM MasterMind Bedienungsanleitung Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 29
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
14
FNSP- Function Key Special Support
(MIDI Ch range: CH01 - CH16, CH-- (disabled) , Default value: CH--)
(CC number range: c001 - c127, c--- or c000 (disabled), Default value: c---)
Sets a special MIDI channel and CC number. On any patch where the Func parameter is set to this particular MIDI
channel and CC number, the Function button will operate as a momentary switch. The Function button will operate
normally (as a latching switch) otherwise. This is typically used for tap tempo support on certain MIDI devices that
require momentary switching. Press 2 / Program/CC Number to select the CC number and 5 / MIDI Ch to select the
MIDI Channel. (note: this feature is disabled if the CC number is set to c000 (bank select))
RENA - Remote Enable
(Enable range: On, OFF, Default value: OFF)
Turning this parameter on enables remote access mode, where two or more MasterMinds can be linked together and
synchronized. See the Remote Access section for more details. Press 3 / CC On/Off to toggle this parameter on or off. If
you’re connecting something other than a MasterMind to the Remote In port, this parameter should be set to OFF.
rCCh - MIDI Receive Channel
(MIDI Ch range: CH01 - CH16, CH-- (MIDI receive disabled) , Default value: CH--)
Sets the MIDI channel on which the MasterMind receives Program Change messages. Press 5 / MIDI Ch to select the
MIDI Channel. If this is enabled, a Program Change message coming in on the Remote In port will cause a preset to be
selected and the MasterMind will send all of the MIDI messages for that preset, just as if the preset was selected from
the front panel buttons.
prdI - Preset Display
(Preset Display range: On, OFF, Default value: Off)
Sets the format of the preset display. Off sets the display the normal bank/preset display as described earlier in the
manual. On sets the display to a sequential program number (starting at program 1). When this parameter is on, bank 0
will have presets 1 through 5, bank 1 will have presets 6 through 10, bank 2 will have presets 11 through 15, etc.
IA - Instant Access
(Instant Access range: On, OFF, Default value: OFF)
Turning on this parameter will enable Instant Access mode. With this parameter on, the Function button will activate
Instant Access mode, regardless of any other Function button related settings. See the Instant Access Mode section for
more details.
IA1 - Instant Access 1 Mode
(Instant Access Mode range: LAT, PULS, Grp, Default value: LAt)
This controls the behavior of Instant Access button 1. LAT(latching) is the default behavior: each press of the IA button
toggles it between on and off. PuLs (momentary pulse) means that the switch stays on while you’re holding the button
down, but turns off as soon as you release the button (this is particularly useful for tap tempo control). Grp (group)
means that pressing this switch will turn off all other IA switches that are set to Grp the MasterMind will insure that
no more than one switch in the group can be on at a time.
IA2 - Instant Access 2 Mode
(Instant Access Mode range: LAT, PULS, Grp, Default value: LAt)
This controls the behavior of Instant Access button 2. LAT(latching) is the default behavior: each press of the IA button
toggles it between on and off. PuLs (momentary pulse) means that the switch stays on while you’re holding the button
down, but turns off as soon as you release the button (this is particularly useful for tap tempo control). Grp (group)
means that pressing this switch will turn off all other IA switches that are set to Grp the MasterMind will insure that
no more than one switch in the group can be on at a time.
IA3 - Instant Access 3 Mode
(Instant Access Mode range: LAT, PULS, Grp, Default value: LAt)
This controls the behavior of Instant Access button 3. LAT(latching) is the default behavior: each press of the IA button
toggles it between on and off. PuLs (momentary pulse) means that the switch stays on while you’re holding the button
down, but turns off as soon as you release the button (this is particularly useful for tap tempo control). Grp (group)
means that pressing this switch will turn off all other IA switches that are set to Grp the MasterMind will insure that
no more than one switch in the group can be on at a time.
Seitenansicht 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 28 29

Kommentare zu diesen Handbüchern

Keine Kommentare